XJIPC OpenIR  > 省部共建新疆特有药用资源利用重点实验室
Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography
Yang Yi; Gu Dongyu; Aisa Haji Akber; Ito Yoichiro
2010
Source PublicationJOURNAL OF CHROMATOGRAPHY A
ISSN219673
Volume1217Issue:18Pages:3167-3170
AbstractThe performance of type-I high-speed counter-current chromatography was evaluated by changing the column inclination against the rotating centrifugal force field. The separations were performed with two different solvent systems composed of 1-butanol-acetic acid-water (4.75:0.25:5, v/v) (BAW) and hexane-ethyl acetate-methanol-0.1. M HCl (1:1:1:1, v/v) (HEMW) using dipeptides and DNP-amino acid as test samples, respectively. A set of short coiled columns connected in series is mounted around the holder hub in two different ways: in the parallel orientation, all column units are arranged in parallel to each other and mounted on the holder at various angles against the horizontal plane. In the zigzag configuration, the neighboring units of the same column are mounted symmetrically forming various angles apart. In the parallel configuration, for both the BAW and HEMW systems, Sf (the retention of stationary phase) first increased as the column angle decreased from 90° to 60° and then decreased, as the column angle further decreased from 60° to 0°, while Rs (peak resolution) continually declined over the entire column angle range from 90° to 0°. But, for both solvent systems, with the zigzag configuration, retention of stationary phase and resolution both decreased as the column angle decreased from 90° to 0°. In general, Sf and Rs for separation of dipeptides in the BAW system, from 90° to 15°, is better for the parallel orientation than for the zigzag configuration. However, at 0°, Sf and Rs are better for the zigzag orientation. In the DNP-amino acid separation with the HEMW system, retention of the stationary phase and Rs for the parallel orientation is better than that for the zigzag orientation from 90° to 30°, whereas from 30° to 0° the results are opposite. Over all results of our studies revealed that the formally used column orientation [5] at 90° inclination yields the highest peak resolution in both solvent systems.
KeywordType-i Counter-current Chromatography Coil Planet Centrifuge The Angle Against The Rotating Centrifugal Force Field Retention Of The Stationary Phase Resolution Dipeptide Dnp-amino Acid
Subject AreaBiochemistry & Molecular Biology ; Chemistry
DOI10.1016/j.chroma.2010.03.004
Indexed BySCI
WOS IDWOS:000277373800020
Citation statistics
Cited Times:9[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.xjipc.cas.cn/handle/365002/1784
Collection省部共建新疆特有药用资源利用重点实验室
AffiliationNHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Key Lab Chem Plant Resources Arid Reg, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China
Recommended Citation
GB/T 7714
Yang Yi,Gu Dongyu,Aisa Haji Akber,et al. Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography[J]. JOURNAL OF CHROMATOGRAPHY A,2010,1217(18):3167-3170.
APA Yang Yi,Gu Dongyu,Aisa Haji Akber,&Ito Yoichiro.(2010).Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography.JOURNAL OF CHROMATOGRAPHY A,1217(18),3167-3170.
MLA Yang Yi,et al."Evaluation of the effect of column orientation in type-I high-speed counter-current chromatography".JOURNAL OF CHROMATOGRAPHY A 1217.18(2010):3167-3170.
Files in This Item:
File Name/Size DocType Version Access License
evaluation of the ef(240KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yang Yi]'s Articles
[Gu Dongyu]'s Articles
[Aisa Haji Akber]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yang Yi]'s Articles
[Gu Dongyu]'s Articles
[Aisa Haji Akber]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yang Yi]'s Articles
[Gu Dongyu]'s Articles
[Aisa Haji Akber]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: evaluation of the effect of column orientation in type-i high-speed counter-current chromatography.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.