XJIPC OpenIR  > 资源化学研究室
Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge
Yang Yi; Gu Dongyu; Aisa Haji Akber; Ito Yoichiro
2010
Source PublicationJournal of Chromatography A
ISSN219673
Volume1217Issue:48Pages:7612-7615
AbstractOptimal positions of coiled separation columns on the type-I centrifuge were determined for four typical two-phase solvent systems to obtain the best separation efficiency (resolution and retention of stationary phase) for each with a suitable set of test samples. A set of short coiled columns is connected in series and mounted around the holder hub in four different ways: (model A) the tail of one unit with left-handedness was connected to the head of the next unit with right-handedness (TL-HR); (model B) the tail of one unit with left-handedness was connected to the tail of the next unit with right-handedness (TL-TR); (model C) the tail of one unit with left-handedness was connected to the tail of the next unit with left-handedness (TL-TL); (model D) the tail of one unit with left-handedness was connected to the head of the next unit with left-handedness (TL-HL). The results indicated that the performance of model D was the best among the four models. High revolution speed (800. rpm) is favorable to separation using the moderately hydrophobic solvent system of hexane-ethyl acetate-methanol-0.1. M HCl (1:1:1:1, v/v) (HEMW), while lower revolution speed (600. rpm) is beneficial to the separation with polar solvent system of 1-butanol-acetic acid-water (19:1:20, v/v) (BAW).
KeywordCompact Type-i Coil Planet Centrifuge Counter Current Chromatography Mounted Column Models Dnp-amino Acids Dipeptides Retention Of The Stationary Phase Resolution
Subject AreaBiochemistry & Molecular Biology ; Chemistry
DOI10.1016/j.chroma.2010.10.012
WOS IDWOS:000284672400021
Citation statistics
Cited Times:7[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.xjipc.cas.cn/handle/365002/1776
Collection资源化学研究室
AffiliationNHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Key Lab Xinjiang Indigenous Med Plants Resource U, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China
Recommended Citation
GB/T 7714
Yang Yi,Gu Dongyu,Aisa Haji Akber,et al. Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge[J]. Journal of Chromatography A,2010,1217(48):7612-7615.
APA Yang Yi,Gu Dongyu,Aisa Haji Akber,&Ito Yoichiro.(2010).Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge.Journal of Chromatography A,1217(48),7612-7615.
MLA Yang Yi,et al."Evaluation on the performance of four different column models mounted on the compact type-I coil planet centrifuge".Journal of Chromatography A 1217.48(2010):7612-7615.
Files in This Item:
File Name/Size DocType Version Access License
evaluation on the pe(401KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yang Yi]'s Articles
[Gu Dongyu]'s Articles
[Aisa Haji Akber]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yang Yi]'s Articles
[Gu Dongyu]'s Articles
[Aisa Haji Akber]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yang Yi]'s Articles
[Gu Dongyu]'s Articles
[Aisa Haji Akber]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: evaluation on the performance of four different column models mounted on the compact type-i coil planet centrifuge.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.