XJIPC OpenIR  > 省部共建新疆特有药用资源利用重点实验室
NOVEL DESIGN FOR CENTRIFUGAL COUNTER-CURRENT CHROMATOGRAPHY: III. SAW TOOTH COLUMN
Yang Yi; Aisa Haji Akber; Ito Yoichiro
2010
Source PublicationJOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES
ISSN10826076
Volume33Issue:6Pages:846-858
AbstractThe toroidal coil using an equilateral triangular core and zigzag pattern column have improved both retention of the stationary phase and peak resolution of the conventional toroidal coil in centrifugal counter-current chromatography. To further improve the retention of stationary phase and peak resolution, a novel saw tooth column was designed and the performance of the system was evaluated at various flow rates. The results indicated that both retention of the stationary phase and peak resolution were improved as the flow rate was decreased and at a flow rate of 0.005mL/min the resolution is remarkably increased. Modification of the tubing called flat-twisted tubing further improved the peak resolution without increasing the column pressure. With decreased column length at a capacity of about 0.2mL, resolution of the saw tooth column was 1.02.
KeywordCounter-current Chromatography Dipeptide Dnp-amino Acid Resolution Retention Of The Stationary Phase Saw Tooth Column
Subject AreaBiochemistry & Molecular Biology ; Chemistry
DOI10.1080/10826071003684547
Indexed BySCI
WOS IDWOS:000277574500012
Citation statistics
Cited Times:10[WOS]   [WOS Record]     [Related Records in WOS]
Document Type期刊论文
Identifierhttp://ir.xjipc.cas.cn/handle/365002/1775
Collection省部共建新疆特有药用资源利用重点实验室
AffiliationNHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Xinjiang Key Lab Plant Resources & Nat Prod Chem, Xinjiang Tech Inst Phys & Chem, Urumqi, Peoples R China;Chinese Acad Sci, Grad Univ, Beijing, Peoples R China
Recommended Citation
GB/T 7714
Yang Yi,Aisa Haji Akber,Ito Yoichiro. NOVEL DESIGN FOR CENTRIFUGAL COUNTER-CURRENT CHROMATOGRAPHY: III. SAW TOOTH COLUMN[J]. JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES,2010,33(6):846-858.
APA Yang Yi,Aisa Haji Akber,&Ito Yoichiro.(2010).NOVEL DESIGN FOR CENTRIFUGAL COUNTER-CURRENT CHROMATOGRAPHY: III. SAW TOOTH COLUMN.JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES,33(6),846-858.
MLA Yang Yi,et al."NOVEL DESIGN FOR CENTRIFUGAL COUNTER-CURRENT CHROMATOGRAPHY: III. SAW TOOTH COLUMN".JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES 33.6(2010):846-858.
Files in This Item:
File Name/Size DocType Version Access License
novel design for cen(1102KB)期刊论文作者接受稿开放获取CC BY-NC-SAView Application Full Text
Related Services
Recommend this item
Bookmark
Usage statistics
Export to Endnote
Google Scholar
Similar articles in Google Scholar
[Yang Yi]'s Articles
[Aisa Haji Akber]'s Articles
[Ito Yoichiro]'s Articles
Baidu academic
Similar articles in Baidu academic
[Yang Yi]'s Articles
[Aisa Haji Akber]'s Articles
[Ito Yoichiro]'s Articles
Bing Scholar
Similar articles in Bing Scholar
[Yang Yi]'s Articles
[Aisa Haji Akber]'s Articles
[Ito Yoichiro]'s Articles
Terms of Use
No data!
Social Bookmark/Share
File name: novel design for centrifugal counter-current chromatography iii saw tooth column.pdf
Format: Adobe PDF
All comments (0)
No comment.
 

Items in the repository are protected by copyright, with all rights reserved, unless otherwise indicated.