Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography
Yang Yi; Gu Dongyu; Aisa Haji Akber; Ito Yoichiro
2011
发表期刊JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES
ISSN15700232
卷号879期号:32页码:3802-3805
摘要The performance of protein separation using the figure-8 column configuration in centrifugal countercurrent chromatography was investigated under various flow rates and revolution speeds. The separation was performed with a two-phase solvent system composed of polyethylene glycol 1000/potassium phosphate each at 12.5% (w/w) in water and with lysozyme and myoglobin as test samples. In order to improve tracing of the elution curve, a hollow fiber membrane dialyzer was inserted at the inlet of the UV detector. The results showed that the retention of stationary phase (Sf) and resolution (Rs) increased with decreased flow rate and increased revolution speed. The highest Rs of approximately 1 was obtained at a flow rate of 0.01 mL/min under a revolution speed of 1200 rpm with a 3.4 mL capacity column.
关键词Centrifugal Counter-current Chromatography Figure-8 Column Protein Separation Polymer Phase System Lysozyme Myoglobin Hollow Fiber Membrane Dialyzer
学科领域Biochemistry & Molecular Biology ; Chemistry
DOI10.1016/j.jchromb.2011.10.019
WOS记录号WOS:000298530200004
引用统计
被引频次:6[WOS]   [WOS记录]     [WOS相关记录]
文献类型期刊论文
条目标识符http://ir.xjipc.cas.cn/handle/365002/1449
专题省部共建新疆特有药用资源利用重点实验室
作者单位NHLBI, Bioseparat Technol Lab, Biochem & Biophys Ctr, NIH, Bethesda, MD 20892 USA;Chinese Acad Sci, Key Lab Chem Plant Resources Arid Reg, Xinjiang Tech Inst Phys & Chem, Urumqi 830011, Peoples R China
推荐引用方式
GB/T 7714
Yang Yi,Gu Dongyu,Aisa Haji Akber,et al. Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography[J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,2011,879(32):3802-3805.
APA Yang Yi,Gu Dongyu,Aisa Haji Akber,&Ito Yoichiro.(2011).Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography.JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES,879(32),3802-3805.
MLA Yang Yi,et al."Evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography".JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES 879.32(2011):3802-3805.
条目包含的文件
文件名称/大小 文献类型 版本类型 开放类型 使用许可
evaluation of the pe(363KB)期刊论文作者接受稿开放获取CC BY-NC-SA浏览 请求全文
个性服务
推荐该条目
保存到收藏夹
查看访问统计
导出为Endnote文件
谷歌学术
谷歌学术中相似的文章
[Yang Yi]的文章
[Gu Dongyu]的文章
[Aisa Haji Akber]的文章
百度学术
百度学术中相似的文章
[Yang Yi]的文章
[Gu Dongyu]的文章
[Aisa Haji Akber]的文章
必应学术
必应学术中相似的文章
[Yang Yi]的文章
[Gu Dongyu]的文章
[Aisa Haji Akber]的文章
相关权益政策
暂无数据
收藏/分享
文件名: evaluation of the performance of protein separation in figure-8 centrifugal counter-current chromatography.pdf
格式: Adobe PDF
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。